Under 21 CFR 211.84, pharmaceutical manufacturers are required to test or examine every lot of incoming components including all excipients before releasing them for use in production. Compendial testing is mandatory for every lot without exception. What else is required depends on the material, the applicable monograph, and supplier qualification status. These aren’t optional quality steps. They’re the regulatory baseline.
Supplier CoAs don’t satisfy that requirement on their own, and they don’t catch everything. The documented cases of glycerin and propylene glycol contaminated with diethylene glycol materials that cleared supplier documentation and caused patient fatalities are the most cited examples. But lot-to-lot variability from otherwise reliable suppliers is a more common and less dramatic problem that testing at intake catches before it becomes a manufacturing failure. NJ Labs provides independent raw material and excipient testing for pharmaceutical, nutraceutical, cosmetic, food, and specialty chemical manufacturers covering identity, assay, purity, impurity profiling, physical characterization, and microbiological testing per USP/NF, EP, BP, JP, FCC, and internal specifications.
The table below covers the materials NJ Labs most commonly tests, organized by functional category. Which tests apply to a specific material depends on the monograph, grade, and intended use. Contact NJ Labs to discuss anything not listed.
| Category | Materials (Alphabetical) |
|---|---|
| APIs and Specialty Ingredients | Ascorbic Acid, Aspirin, Caffeine, Creatine, Omega-3-Acid Ethyl Esters, Urea |
| Alcohols and Polymer-Based Ingredients | Benzyl Alcohol, Oleyl Alcohol, Polyethylene Glycol, Polyethylene Oxide, Stearyl Alcohol |
| Cellulose Derivatives and Polymers | Carbomer Homopolymer, Carboxymethyl Cellulose, Copovidone, Crospovidone, Hydroxyethyl Cellulose, Hydroxypropyl Cellulose, Hypromellose, Low-Substituted Hydroxypropyl Cellulose, Methylcellulose, Povidone, Sodium Carboxymethyl Cellulose |
| Excipients and Fillers | Calcium Carbonate, Colloidal Silicon Dioxide, Dicalcium Phosphate, Lactose Monohydrate, Magnesium Stearate, Mannitol, Microcrystalline Cellulose, Sucrose, Talc |
| Functional Ingredients | Glycerin, Sorbitan Monostearate, Sorbitol Solution |
| Gums and Hydrocolloids | Alginates, Gelatin, Guar Gum, Pectin, Sodium Alginate, Xanthan Gum |
| Minerals and Salts | Magnesium Citrate, Magnesium Oxide, Sodium Chloride, Sodium Hydroxide |
| Preservatives | Methylparaben, Potassium Sorbate, Propylparaben, Sodium Benzoate, Sorbic Acid |
NJ Labs tests raw materials and excipients per USP/NF, EP, BP, JP, and FCC. For full detail on compendial method coverage, see the NJ Labs Pharmaceutical Testing page: https://njlabs.com/industries/pharmaceuticals-testing/
The tests applicable to a specific material are set by the monograph, specification, material grade, and intended use not by a one-size-fits-all panel. The table below outlines the categories of testing NJ Labs performs and the methods used within each.
| Testing Category | Test Types | Methods and Techniques |
|---|---|---|
| Identity Testing | Compendial identification, characterization | FTIR, HPLC/UPLC, GC, UV-Vis spectrophotometry, wet chemistry identification tests per applicable USP, EP, BP, JP, and FCC monograph procedures |
| Assay and Potency | Quantification of principal component | HPLC/UPLC, GC-FID, UV-Vis spectroscopy, titration; method selection determined by the applicable pharmacopeial monograph or internal specification |
| Impurity and Residual Testing | Related substances, elemental impurities, residual solvents, specific impurities | HPLC for related substances; ICP-MS per USP <232>/<233> for elemental impurities aligned with ICH Q3D; headspace GC per USP <467> for residual solvents (Class 1, 2, and 3 per ICH Q3C); targeted methods for 1,4-dioxane, benzene, and other specified contaminants |
| Physical and Functional Testing | Physical characteristics, functional properties | Appearance and description; bulk and tapped density per USP <616>; loss on drying per USP <731>; moisture by Karl Fischer per USP <921>; particle size per USP <429>; pH per USP <791>; specific gravity per USP <841>; viscosity per USP <911>/<912> |
| Microbiological Testing | Microbial limits, specified organisms, pathogen testing | Total aerobic microbial count (TAMC) and total yeast and mold count (TYMC) per USP <61>; specified microorganisms per USP <62>; pathogen testing as applicable to the material and intended use |
Identity testing is non-negotiable. Under 21 CFR 211.84, it must be performed on every lot of every incoming component; there’s no waiver available based on supplier history or CoA documentation. The test answers a single question: is this material what it’s supposed to be? Which technique is used depends on the material and the monograph. Common approaches include:
Manufacturing processes, source materials, and supply chain handling all create opportunities for impurities to enter raw materials. Left undetected, those impurities can show up in the finished product as safety concerns, stability failures, or regulatory findings.
Elemental impurity limits for pharmaceutical materials are set by USP <232> and <233>, based on the ICH Q3D framework. NJ Labs uses ICP-MS for this testing, which detects lead, arsenic, cadmium, mercury, and other elements at ppb and ppt levels. Because excipients contribute to the total elemental impurity burden in the finished product, excipient-level data is part of the finished product risk assessment.
Excipients and APIs made through organic synthesis or extraction may carry residual solvents. NJ Labs tests for these by headspace GC per USP <467>, covering Class 1, 2, and 3 solvents. Worth noting for certain excipient classes: polyethylene glycols, polysorbates, and povidone have known associations with 1,4-dioxane and benzene as process-related impurities both Class 1 solvents that require specific attention.
Related substance testing looks for chemical impurities and degradation products structurally similar to the principal component. These are quantified by HPLC and compared against the limits in the applicable monograph or internal specification.
Most raw materials and excipients aren’t sterile and aren’t expected to be but they still carry a bioburden that needs to stay within limits appropriate for the finished product and its route of administration. Materials for oral products have different acceptable limits than those used in topicals or ophthalmics, and those limits are set by the monograph or the finished product specification.
NJ Labs performs:
The applicable microbial limits depend on the intended use and dosage form defined in the pharmacopeial monograph, the manufacturer’s internal spec, or derived from finished product requirements.
A supplier’s Certificate of Analysis documents their own test results for a specific lot. FDA regulations require pharmaceutical manufacturers to verify that data through independent testing or through a validated reduced testing program supported by a documented supplier qualification history.
NJ Labs runs CoA verification testing to independently confirm a material’s identity, assay, purity, and other critical quality attributes. That independent result is what provides the documented evidence the FDA expects to see that incoming components were actually tested, not just reviewed on paper, before they were released into production.
Pharmaceutical manufacturers testing incoming APIs and excipients under 21 CFR 211.84 need documented identity and purity data before materials enter production. NJ Labs supports incoming inspection programs, supplier qualification testing, and regulatory submission documentation for NDA, ANDA, IND, and DMF filings.
21 CFR Part 111 requires dietary supplement manufacturers to verify that incoming raw materials meet identity specifications before use. NJ Labs tests dietary supplement ingredients, amino acids, vitamins, minerals, botanical extracts, and functional ingredients against USP/NF and FCC specifications for lot release and compliance documentation.
Cosmetic manufacturers use raw material testing to support EU Cosmetics Regulation safety assessments, internal quality programs, and retailer compliance requirements. NJ Labs tests cosmetic raw materials for identity, purity, and microbiological quality.
Suppliers selling into pharmaceutical manufacturers are often required to provide full compendial CoA data. NJ Labs performs full and partial pharmacopeial monograph testing against USP/NF, EP, BP, JP, and FCC specifications for suppliers who need to document compliance for their pharmaceutical customers.
Testing raw materials across identity, assay, impurity, physical, and microbiological parameters typically means coordinating across multiple laboratories each with its own documentation, timelines, and chain-of-custody requirements. NJ Labs covers all of those under one quality system, which simplifies incoming inspection programs considerably.
What makes this page specifically useful: NJ Labs tests against FCC in addition to USP/NF, EP, BP, and JP relevant for food-grade excipients and dietary supplement ingredients that don’t fall under pharmaceutical monographs alone. CoA verification testing is a core service, not an add-on. And the materials capability list above covers the specific excipients and raw materials most commonly encountered in pharmaceutical and nutraceutical incoming inspection programs. For NJ Labs’ full credentials, accreditations, and analytical method depth, see the Pharmaceutical Testing page: https://njlabs.com/industries/pharmaceuticals-testing/
NJ Labs tests raw materials and excipients for identity, assay, impurity, physical, and microbiological parameters per USP/NF, EP, BP, JP, FCC, and internal specifications.
To discuss your testing needs, it helps to have the following ready: material name and grade, applicable standard or specification, required tests and acceptance criteria, and any batch release or submission timeline. Contact NJ Labs today. All discussions are handled under confidentiality.
Raw material testing is how pharmaceutical manufacturers confirm that incoming APIs, excipients, solvents, and other components are what they’re supposed to be and meet the specifications they’re required to meet before going into production. Under 21 CFR 211.84, identity testing is required for every lot of every component. Assay, purity, and microbial testing requirements are set by the material type, applicable monograph, and internal specifications.